• Products and Selection
  • Services and Commerce
  • How do I choose between a gear pump and a magnetic drive gear pump?

    Select a gear metering pump for standard operating conditions; choose a magnetic drive gear pump when the medium is corrosive or zero leakage is required to prevent shaft seal leakage.

  • How do I select the displacement of a gear metering pump?

    First confirm the fluid viscosity and desired flow rate per revolution, then choose a model with a displacement closest to the 0.05–200 cc/r range, and finally match the motor speed and reduction ratio.

  • Can an accuracy of ±0.5% meet my mixing ratio requirements?

    ±0.5% refers to repeatability. For two-component mixing ratios, it is recommended to allow 1.5 times the margin and require a factory calibration report.

  • What materials and seals are suitable for high-temperature colloids at 350℃?

    The pump body and gears can be selected from 440C, high-speed steel, or Stellite; use a canned motor seal or magnetic drive seal, capable of withstanding 350℃ high-temperature colloids.

  • Which type of pump should I choose for strong acid and strong alkali resistant applications?

    Select wetted parts made of PTFE or Hastelloy, equipped with a magnetic drive seal structure to prevent direct contact between the medium and metal or sealing components.

  • Can one pump deliver two components simultaneously?

    Two-component dispensing requires two metering pumps with interlocked control, which can be set according to the A/B ratio and started/stopped in sync.

  • Is the pressure loss high for gear flow meters?

    Under normal operating conditions, pressure loss is approximately 0.02–0.05 MPa; sizing calculations consider flow rate and viscosity, and a plate-type configuration can be provided separately for high-pressure applications.

  • Are there any installation orientation requirements for flow meters?

    Yes, there are orientation requirements. The inlet and outlet of both the pump and flow meter must be installed according to the marked direction; reversing the flow will reduce metering accuracy and affect seal life.

  • Can it be paired with a control cabinet and touchscreen?

    Yes, it is supported. The standard control cabinet includes a touchscreen, inverter, and mixing program, and can interface with on-site PLCs and host computers.

  • What is the standard delivery time?

    For standard models, 7–15 business days; for custom materials or complete systems, approximately 20–30 business days.

  • Do you support customization of non-standard flow paths?

    Yes. We can provide non-standard designs for flow paths, inlet/outlet orientations, and mounting hole patterns, provided you supply the fluid medium and operating condition parameters.

  • Can you provide material certificates and test reports?

    We can provide material certificates and factory calibration records; CE, explosion-proof, and metrology calibration certificates are available on a per-project basis.

  • Are on-site installation and commissioning included in the quotation?

    The standard quotation includes installation guidance and initial commissioning; travel and lifting costs are billed separately based on actual expenses and can be itemized in the quote.

  • How are consumables and spare parts supplied?

    We keep common consumables such as gears, shafts, and seals in stock, with shipment within 3–5 business days after order placement; long-term customers may maintain safety stock levels.

午腾测控微信公众号 Phone: 15301979852 (Mr. Liu) brave@wtckyb.com Leave a message online