The key to handling strong acid and strong alkali conditions lies not in the “pump type” but in the combination of “wetted part material + sealing configuration”; the gear pump design itself is suitable.
Prefer magnetic couplings or PTFE bellows seals to completely prevent contact between the process fluid and metal elastomeric components; mechanical seals are prone to end-face corrosion and crystallization-induced seizing in strong alkalis and are not recommended for long-term use.
Medium name and concentration, temperature, presence and size of solid particles, flow rate and discharge pressure, and whether trace external leakage is permissible. Different concentrations and temperatures can lead to entirely different material compatibility conclusions—for example, dilute sulfuric acid can be handled by 316L stainless steel, while concentrated sulfuric acid requires high-silicon stainless steel or Hastelloy. We will provide a material compatibility confirmation table during the selection phase to prevent intergranular corrosion on-site.