Products and Selection

Can one pump deliver two components simultaneously?

No. A single gear pump has only one inlet and one outlet, with a single-channel internal flow path. When two components enter the same pump chamber, they will mix inside the pump, making proportional control impossible and potentially causing blockage due to reaction or curing.

Standard Practice for Two-Component Systems

  • Two metering pumps separately deliver components A and B, each with independent speed control. They operate in linked mode according to a set ratio, starting and stopping synchronously.
  • Proportional control methods: Master–slave tracking (pump B follows pump A’s speed proportionally), line-following (pump flow rates are adjusted based on production line speed), or closed-loop flow control (each pump is equipped with a gear flow meter for real-time correction).
  • Mixing stage: Use a static mixer (simple structure, maintenance-free) or a dynamic mixing valve (suitable for high-viscosity or easily stratifying colloids). The mixture should be used immediately to prevent curing while remaining in the pipeline.

Complete Solutions

The station’s two-component ratio control system integrates both pumps, a control cabinet, a touchscreen, inverters, and ratio programming into a single unit. It can store multiple formulas, display real-time flow rates and cumulative totals for both streams, log alarms and batch data, and provides a Modbus interface for connecting to the production line PLC. If the ratio between the two components varies widely (e.g., 1:20), it is recommended to use small-displacement pumps or servo drives for the low-flow stream to ensure stable metering at low flow rates.

Still haven't solved your application issue? Send us details of the medium, temperature, flow rate, and pressure, and our engineers will help you calculate and select the appropriate equipment. Contact Technical Engineer Back to FAQs
午腾测控微信公众号 Phone: 15301979852 (Mr. Liu) brave@wtckyb.com Leave a message online