±0.5% is the metering accuracy of the pump under calibrated operating conditions and within its rated speed range (including repeatability and linearity). It describes how consistently a single pump delivers a given volume per revolution, but it does not equate to the final system’s mixing ratio accuracy.
In a two-component system with one pump on each channel (A and B), the worst-case mixing deviation is approximately the sum of the errors from both channels, around ±1%. If the displacement rates of the two channels differ significantly (e.g., 10:1), the error from the lower-flow channel carries greater weight.
If the process requires a mixing ratio accuracy of ±1%, select pumps rated at ±0.5%; for ±0.5% requirements, choose individual pumps rated at ±0.3% or adopt a closed-loop solution. This margin compensates for additional deviations caused by backpressure fluctuations, viscosity changes with temperature, and pipeline pulsations.
It is recommended to request a factory‑calibrated report for each unit (including flow‑vs‑speed curves). Additionally, install a gear flow meter in series at critical mixing stations for real-time correction, forming a closed loop that can maintain stable system accuracy within ±0.5%.