Under normal viscosity and flow conditions, the pressure drop of a gear flow meter is approximately 0.02–0.05 MPa, which is relatively low—comparable to oval gear and turbine meters—and significantly lower than that of throttling differential pressure flow meters.
A pressure drop can cause downstream pressure to fall below upstream pressure. If the downstream side includes restrictive components such as nozzles or die heads, flow rate may drift in response to changes in pressure drop, necessitating pressure compensation after the meter or employing closed-loop control. Gear flow meters are positive displacement devices; as long as the fluid fully fills the chambers, measurement accuracy remains unaffected by pressure—this represents their advantage over differential pressure instruments.
During installation, ensure straight pipe lengths of 5D upstream and 3D downstream. If the pump outlet is located immediately adjacent to the flow meter, install a pulsation damper; otherwise, alternating forces on the gears will compromise readings and accelerate wear.