Displacement refers to the theoretical volume delivered per revolution of the pump shaft, measured in cc/r. Actual flow is calculated as "displacement × speed × volumetric efficiency," so larger displacement isn't always better; the key is ensuring the operating speed falls within the pump's optimal range.
Three Steps to Determine Displacement
- Step 1: Calculate per-revolution requirement: Target flow (ml/min) ÷ Planned speed (r/min) = Required displacement. For example, for 60 ml/min at a planned 30 r/min, displacement is approximately 2 cc/r.
- Step 2: Select the nearest standard displacement within the 0.05–200 cc/r range. It's preferable to choose slightly larger and adjust flow by reducing speed, rather than selecting a size that would require continuous full-speed operation.
- Step 3: Verify volumetric efficiency: Higher fluid viscosity and greater outlet pressure increase internal leakage, reducing actual displacement below the theoretical value. For high-viscosity applications, adjust calculations using the manufacturer's viscosity-efficiency curve.
Recommended Speed Range
For standard models, an operating speed of 30–70 r/min is recommended to ensure stable metering while allowing adjustment tolerance as wear occurs. Below 10 r/min, pulsation becomes significant and motor performance at low speeds deteriorates; above 100 r/min, wear accelerates and cavitation may occur on the suction side. When extremely low flow rates are needed, use a large-displacement pump with a reduction gear ratio instead of running a small-displacement pump at high speed.
Match to Process Requirements
- Low-pressure foaming, precision coating, microdispensing: Small-displacement models of 0.05–3 cc/r.
- Hot-melt adhesives, fiber spinning, resin transfer: 5–50 cc/r, paired with low speeds and heated delivery lines.
- High-flow circulation, filling: 50–200 cc/r; pay attention to inlet/outlet pipe sizes and suction head.