Products and Selection

What materials and seals are suitable for high-temperature colloids at 350℃?

350℃ already exceeds the operational limits of conventional oil seals and PTFE packing; modifications are required simultaneously across material selection, sealing design, and structural engineering.

Impeller Material

  • 440C martensitic stainless steel: Offers excellent hardness and wear resistance, making it suitable for high-temperature colloids containing fillers; it is the standard first choice.
  • High-speed steel gears: Provide higher hardness, ideal for highly filled, strongly abrasive media, though with slightly lower toughness.
  • Stellite alloy: Cladded onto sealing faces and gear end faces, offering superior wear and corrosion resistance, suitable for long-term continuous operation at elevated temperatures.

Sealing Type

  • Metallic labyrinth seals (spring‑energized PTFE or graphite combinations): Withstand temperatures exceeding 300℃. As contact seals, they require periodic replacement.
  • Magnetic seals: Eliminate dynamic seals entirely, achieving zero leakage. For high‑temperature applications, they require samarium‑cobalt magnets and thermal insulation structures.
  • Conventional oil seals combined with PTFE packing are only suitable below 200℃; do not use them under 350℃ operating conditions.

Key Structural Considerations

At high temperatures, significant differential thermal expansion occurs in metals; end‑face clearances must be redesigned to include adequate compensation. Insulation brackets and adjusted coupling spacing between the pump casing and motor are essential to prevent heat transfer to the motor bearings. An insulated jacket around flow passages can prevent colloid solidification during shutdowns. During initial startup, a controlled heating curve is recommended to avoid cold‑state forced starts that could damage the gears.

Additionally, verify the actual viscosity of the process fluid at 350℃ and check for gas evolution. When viscosity drops below 200 cP, internal leakage increases markedly, necessitating redesign—such as reducing clearance gaps or lowering rotational speed.

Still haven't solved your application issue? Send us details of the medium, temperature, flow rate, and pressure, and our engineers will help you calculate and select the appropriate equipment. Contact Technical Engineer Back to FAQs
午腾测控微信公众号 Phone: 15301979852 (Mr. Liu) brave@wtckyb.com Leave a message online