For high-temperature adhesives operating continuously above 150°C, differences in thermal expansion between seals and the pump housing are the main causes of leakage and seizing.
For high-temperature adhesives operating continuously above 150°C, differences in thermal expansion between seals and the pump housing are the main causes of leakage and seizing.
Hot-melt adhesive coating systems operate continuously above 150°C. Due to differential thermal expansion among pump housing, gears, and seals, clearance fits suitable at room temperature may lead to leakage or seizure as temperatures rise.
The most common issue is adhesive seepage at the shaft seal; cured adhesive on the journal acts as an abrasive, further damaging the shaft surface. Next, seals can harden with heat, losing elasticity and resulting in poor compliance due to insufficient rebound. Thirdly, reduced end-face clearance causes direct friction between gear end faces and side plates, decreasing flow rate while increasing operating temperature.
For wetted parts, prioritize 440C stainless steel or high-speed steel; Stellite overlay welding is suitable for highly filled adhesives.
Employ metal labyrinth seals or magnetic couplings, avoiding standard oil seals.
Install thermal insulation brackets between pump housing and motor, and provide axial expansion space at the coupling.
Add insulated jackets to flow passages to maintain temperature during shutdowns and prevent adhesive solidification.
During initial startup, follow a heating curve to preheat. Only feed material after pump housing and piping temperatures reach set points and stabilize for 30 minutes, avoiding cold-state forced starts that damage gears. If shutdown exceeds 2 hours, drain or circulate fresh adhesive through the pump chamber to reduce solidification risk.