Adhesive Delivery System

PI Film Coating: Flow Stability Control for Precision Adhesive Delivery

Consistent coating thickness depends on closed-loop control of adhesive delivery pressure and flow rate; pulsation suppression and pipeline energy storage are two of the most common modification cost items.

齿轮计量泵选型

PI film coating demands high thickness uniformity; even minor fluctuations in glue delivery flow rate directly affect wet film thickness. Therefore, system design should prioritize pressure stability and pulsation suppression.

I. Thickness Uniformity Requirements for Glue Delivery

Coating die heads are restrictive flow elements, where inlet pressure fluctuations are proportionally converted into flow rate variations. Empirically, maintaining inlet pressure fluctuations within ±1% ensures wet film thickness remains stable within the process window.

Instantaneous pulsations from the glue pump, elastic deformation in the tubing, and valve switching can all introduce pressure disturbances, requiring systematic troubleshooting.

II. Two Approaches to Pulsation Suppression

  • Install pulsation dampeners or accumulators at the pump outlet to absorb instantaneous flow peaks.

  • Shorten the pipeline length between the pump and the die head to reduce lag caused by pipeline elasticity.

  • Use screw pumps or parallel dual pumps with phased feeding to reduce single-pump pulsation.

  • Insert gear flow meters at critical stations for closed-loop flow correction.

III. Closed-Loop Control and Routine Maintenance

For closed-loop control, prioritize flow meter feedback supplemented by pressure feedback to prevent drift caused by temperature-induced pressure signal variations. Routine maintenance should focus on monitoring filter differential pressure and damper precharge pressure; replace the filter element promptly when the differential pressure exceeds 0.1 MPa.

午腾测控微信公众号 Phone: 15301979852 (Mr. Liu) brave@wtckyb.com Leave a message online